Air To Water Split
Water Cycle
Specialized for regions with specific plumbing requirements. Uses secondary heat exchangers to transfer energy through high-density liquid mediums.

Advanced Secondary Cycle Plumbing Integration.
Engineered for properties that require customized water-cycle circulation loops or integration with hydronic underfloor heating. The Air to Water Split utilizes secondary heat exchangers to transfer energy from the ambient air to a closed-loop system, providing precise thermal parameters and architectural flexibility for complex layouts.
Up to 75% Savings
Absorbs ambient air energy to heat water, drastically reducing monthly electricity bills compared to standard electric geysers.
Anti-Corrosive Shielding
Equipped with glass enamel lined tanks and micro-channel external coils to prevent scale buildup and handle hard water conditions.
All-Weather Operation
Operates continuously through cold winters, monsoon humidity, and extreme summer ambient temperatures.
See the engineering up close.
Real product photography of the Water Cycle equipment, finishes, and core assemblies.


Precision Engineering Inside.
The Water Cycle lineup brings together safety, efficiency, and durability systems selected for high-performance thermal heating. Equipment varies by model and capacity.
Tube In Shell Heat Exchanger
High-flow concentric tubes maximize heat exchange rates in commercial and water-cycle circuits.
Hot & Cold Water Option
Supports dual-mode operations to supply both heated utility water and chilled water lines.
Glass Enamel Coated Tank
Fired at 850°C, the composite glass layer shields the steel vessel against pressure fatigue and hard water wear.
50mm PUF Insulation
High-density polyurethane foam casing reduces thermal standby loss over 24-hour cycles.
High Pressure Resistance Up To 8 Bar
Heavy-duty structural vessel handles multi-story plumbing and pressure pump configurations.
Electric Heater with Emerson Control
Dual-safety thermostat system prevents overheating, backed by trusted Emerson engineering.
System Dimensions & Performance.
Detailed parameters for the Air To Water Split lineup. Compare model outputs and structural capacities to fit your project blueprint.
Heat Pump Outdoor Specifications (Water Cycle)
| Model Parameters | AHHPWC-200/75View Details | AHHPWC-300/75View Details | AHHPWC-300/118View Details | AHHPWC-400/161View Details | AHHPWC-500/161View Details | AHHPWC-500/204View Details |
|---|---|---|---|---|---|---|
| Rated Heating Capacity (Watts) | 3500 | 3500 | 5000 | 7200 | 7200 | 9500 |
| Yield in Heat Pump Mode (Ltr/Hr) | 75 | 75 | 118 | 161 | 161 | 204 |
| Heat Pump Input Power (Watts) | 850 | 850 | 1250 | 1750 | 1750 | 2300 |
| Power Supply (V/Ph/Hz) | 220/1/50 | 220/1/50 | 220/1/50 | 220/1/50 | 220/1/50 | 220/1/50 |
| Heat Pump Noise Level DB (A) | 52 | 52 | 52 | 52 | 52 | 52 |
| Refrigerant / Charge Volume | R410a / 800g | R410a / 800g | R410a / 800g | R410a / 1950g | R410a / 1950g | R410a / 2200g |
| Compressor Make | HIGHLY | HIGHLY | HIGHLY | HIGHLY | HIGHLY | HIGHLY |
| Operating Ambient Temp Range (°C) | -5 ~ 43 | -5 ~ 43 | -5 ~ 43 | -5 ~ 43 | -5 ~ 43 | -5 ~ 43 |
| Heat Pump Net Weight (kg) | 28 | 28 | 34 | 48 | 48 | 52 |
| Heat Pump Size (LxDxH mm) | 765x260x530 | 765x260x530 | 765x260x530 | 800x300x540 | 800x300x540 | 830x320x650 |
Water Tank Specifications
| Model Parameters | AHHPWC-200/75View Details | AHHPWC-300/75View Details | AHHPWC-300/118View Details | AHHPWC-400/161View Details | AHHPWC-500/161View Details | AHHPWC-500/204View Details |
|---|---|---|---|---|---|---|
| Capacity (Ltr) | 200 | 300 | 300 | 400 | 500 | 500 |
| Tank Material | Steel with Glass Enamel Coating | Steel with Glass Enamel Coating | Steel with Glass Enamel Coating | Steel with Glass Enamel Coating | Steel with Glass Enamel Coating | Steel with Glass Enamel Coating |
| Tank Inside Coating | Glass Enamel Coating | Glass Enamel Coating | Glass Enamel Coating | Glass Enamel Coating | Glass Enamel Coating | Glass Enamel Coating |
| Type of Heat Exchanger | Micro Channel Outer Side (Aluminium Alloy) | Micro Channel Outer Side (Aluminium Alloy) | Micro Channel Outer Side (Aluminium Alloy) | Micro Channel Outer Side (Aluminium Alloy) | Micro Channel Outer Side (Aluminium Alloy) | Micro Channel Outer Side (Aluminium Alloy) |
| Tank Out Shell Material / Thickness | Stainless Steel / 0.5mm | Stainless Steel / 0.5mm | Stainless Steel / 0.5mm | Stainless Steel / 0.5mm | Stainless Steel / 0.5mm | Stainless Steel / 0.5mm |
| Tank Insulation Thickness (mm) | 50 | 50 | 50 | 50 | 50 | 50 |
| Tank Net Weight / Gross Weight (kg) | 50 / 250 | 75 / 375 | 75 / 375 | 92 / 492 | 110 / 610 | 110 / 610 |
| Electric Backup Heater (Watts) | 2000 | 3000 | 3000 | 3000 | 3000 | 3000 |
| Tank Outline Size (Diameter x Height mm) | ф500 * 1390 | ф600 * 1530 | ф600 * 1530 | ф650 * 1630 | ф700 * 1795 | ф700 * 1795 |
Worry-Free Long-Term Warranty.
We stand behind our materials and manufacturing quality. Every Air To Water Split is backed by a comprehensive warranty coverage package to secure your building investments.
Covers all internal electronics, safety valves, wiring circuits, and control nodes against defects.
Guarantees the glass enamel coated steel pressure storage tank against leaks or structural splits.
Need Help Choosing The Right Heat Pump?
Every building's layout is unique. Submit your project requirements below to get a specialized sizing analysis and quote for the Air To Water Split from our engineers.